Brand Name: AOBO
Model Number: AOBO-W style HEPA AIR filters
Place of Origin: Shandong, China (Mainland)
Condition: New
Efficiency: H13
Construction: Box Filter
Filtration Grade: Hepa Filter
Medium Material: Synthetic Fiber
Certification: ISO9001, ISO14001
After-sales Service Provided: Overseas third-party support available
Standard specification
Item |
Nominal Dimensions Width×Lendth×Thickness mm (Inches) |
Air Flow (m3/h) 2.5m/s
|
Initial resistance (Pa) |
Efficiency EN 1822 |ASHRAE52.2 |
|
AOBO |
592 × 292 × 292 (23.3 × 11.5 × 11.5) |
1700 |
230 |
H13 |
MERV 16+ |
592 × 592 × 292 (23.3 × 23.3 × 11.5) |
3400 |
285 |
H13 |
MERV 16+ |
*According to user requirements to customize different specifications and types of filters
Specification
Frame: |
Polypropylene |
Efficiency: |
H13(EN 1822): >=99.95% at MPPS >=99.99% at 0.3um |
Separators: |
Hot melt |
Temperature: |
90C/ 194F |
Media: |
Wet-laid glass fiber |
Humidity: |
<= 100% RH |
Sealant: |
Polyurethane |
Recommended final pressure drop: |
<= 600 Pa |
Gasket: |
Endless polyurethane |
Individually tested according to EN 1822 |
Our team will listen, find that any user's filtration system present situation and problems, and then, tailor the most suitable management method for user's filtration system. the only thing users need to do is: wait for clean air head on and enjoy it.
STEP1 Listen to, communicate, found the problem: 1) Record the problem by listening to communication with users.2) find the possible causes of problem, and find that there may be a new problem
STEP2 Summarize problem, put forward the maintenance plan: 1) Collect all of the problems about user's filtration system; 2) According to the existing problems, tailor the maintenance plan for user.
STEP3 Provide technical support, training and consulting services: 1) According to maintenance plan start technical communication with customers, discuss improvement opinion 2) Perfect and optimize the maintenance plan; 3) Provide technical training, support, consulting, services needed by users
STEP4 Set up user profile: According to the filtration system configuration and maintenance plan, establish archives for the customer.
STEP5 Information feedback: Agreed time period as the maintenance period , we will collect the recorded parameters , maintenance workload as well as recommendations aim to the new problems founded , and put it into report to submit to users.
Increasing the Quality
Cost reduction
Reduction Admin costs
Reduction store costs
Service-Engineer on site